Fail-Safe Chart
Hybrid system indicator:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Hybrid system indicator signal is interrupted |
|
Normal data is received |
Fuel signal (Fuel injection signal):
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| While power switch is ON (IG), fuel injection signal is interrupted for 60 seconds | Fuel gauge calibration is performed using average fuel consumption data | Power switch is turned from OFF to ON (IG) and normal data is received |
Fuel signal (Gauge signal):
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| While power switch is ON (IG), sender signal is interrupted for 60 seconds and malfunction signal is received from one of the gauges for 10 to 20 seconds | Needle indicates "E", and warning light comes on | Power switch is turned from OFF to ON (IG) and normal data is received |
Odometer:
| Condition | Fall-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Vehicle speed pulse signal integration value is interrupted for 0 12 seconds | Data received most recently remains displayed | Normal data is received |
A/T shift position indicator:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| "P" to "D" data is interrupted for 3 1 seconds |
|
Normal data is received |
| "P" to "D" data is interrupted | Data received most recently remains displayed (when data is interrupted for 3 1 seconds, shift position indicator goes off) | Normal data is received |
Sports shift position indicator:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Gear position signal is interrupted | Data received most recently remains displayed (when data is interrupted for 3 1 seconds, shift position indicator goes off) | Normal data is received |
| Sports mode indicator and sports mode enable signals are interrupted | Data received most recently remains displayed (when data is interrupted for 3 1 seconds, shift position indicator goes off) | Normal data is received |
SRS warning light:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| While power switch is ON (IG), SRS warning light on/blink request signal (9 0 V or higher) is interrupted for 10 seconds or SRS warning light on/blink request signal (below 9 V) is interrupted for 60 seconds | SRS warning light comes on until power switch is turned OFF | Normal data is received |
ABS warning light:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| While power switch is ON (IG), ABS warning light signal is interrupted for 1 second | ABS warning light comes on until power switch is turned OFF | Normal data is received |
BEAM indicator light:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Headlight HI on instruction signal is interrupted for 10 seconds during CAN bus wake-up mode |
|
Normal data is received |
Brake warning light / yellow (minor malfunction):
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Brake warning light / yellow (minor malfunction) signal, brake level warning light and PKB switch signals are interrupted for 1 second | Brake warning light / yellow (minor malfunction) comes on until power switch is turned OFF | Normal data is received |
CRUISE main indicator light (w/ Dynamic radar cruise control system):
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| CRUISE activate indicator, cruise control warning and radar cruise warning signals are interrupted | Display condition is maintained until power switch is turned OFF | Normal data is received |
Driver side seat belt warning light:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Driver side seat belt buckle switch signal is interrupted for 10 seconds during CAN bus wake-up mode |
|
Normal data is received |
DOOR indicator light:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Driver side courtesy switch, front passenger side courtesy switch, rear door LH courtesy switch, rear door RH courtesy switch and luggage courtesy switch signals are interrupted for 10 seconds during CAN bus wake-up mode |
|
Normal data is received |
Brake warning light / red (malfunction):
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Brake warning light / red (malfunction) signal is interrupted | Brake warning light / red (malfunction) condition is maintained until power switch is turned OFF | Normal data is received |
| While power switch is ON (IG), electric parking brake warning light signal is interrupted for 1 second | Electric parking brake warning light comes on until power switch is turned OFF | Normal data is received |
Fr FOG indicator light:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Front fog light on signal is interrupted for 10 seconds during CAN bus wake-up mode |
|
Normal data is received |
Rr FOG indicator light (except U.S.A.):
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Rear fog light on signal is interrupted for 10 seconds during CAN bus wake-up mode |
|
Normal data is received |
HEAD indicator light:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Headlight LO on instruct signal is interrupted for 10 seconds during CAN bus wake-up mode |
|
Normal data is received |
HEIGHT HIGH indicator light:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| HI light signal is interrupted | HEIGHT HIGH indicator light condition is maintained until power switch is turned OFF | Normal data is received |
Front passenger side seat belt warning light:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Passenger side seat belt buckle switch, passenger side seat occupied/unoccupied signals are interrupted | Front passenger side seat belt warning light condition is maintained until power switch is turned OFF | Normal data is received |
Hybrid POWER indicator light:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Hybrid PWR indicator signal is interrupted | Hybrid POWER indicator light condition is maintained until power switch is turned OFF | Normal data is received |
SLIP indicator light:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Frame data (including SLIP indicator on/blink request signal) is interrupted for 0 9 seconds | SLIP indicator light condition is maintained until power switch is turned OFF | Normal data is received |
Hybrid SNOW indicator light:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Hybrid SNOW indicator signal is interrupted | Hybrid SNOW indicator light condition is maintained until power switch is turned OFF | Normal data is received |
TAIL indicator light:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Taillight on instruct signal is interrupted for 10 seconds during CAN bus wake-up mode |
|
Normal data is received |
Tire pressure warning light:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| While power switch is ON (IG), tire pressure warning signals are interrupted |
|
Normal data is received |
AFS OFF indicator light:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| AFS OFF indicator on request signal is interrupted | AFS OFF indicator light condition is maintained until power switch is turned OFF | Normal data is received |
PARK warning light:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Communication data from electric parking brake ECU is interrupted for 1 second |
|
Normal data is received |
EPS warning light:
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| EPS warning light signal is interrupted for 1 second | EPS warning light condition is maintained until power switch is turned OFF | Normal data is received |