FixVault

Knock Sensor: Inspection

  1. INSPECT KNOCK SENSOR 
    1. Measure the resistance according to the value (s) in the table below.

      Standard resistance 

      STANDARD RESISTANCE

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 120 to 280 kΩ
      Fig 1: Inspecting Knock Sensor
      G05771265Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      If the result is not as specified, replace the sensor.