FixVault

Door Control Switch: Inspection

  1. INSPECT DOOR CONTROL SWITCH ASSEMBLY 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance 

      TESTER CONNECTION SPECIFIED CONDITION CHART

      Tester Connection Switch Condition Specified Condition
      2 (L) - 3 (E) Lock Below 1 Ω
      2 (L) - 3 (E) 4 (UL) - 3 (E) Off 10 kΩ or higher
      4 (UL) - 3 (E) Unlock Below 1 Ω

      If the result is not as specified, replace the control switch assembly.

      Fig 1: Inspecting Door Control Switch Assembly
      G05765344Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Apply battery voltage to the switch connector and check the indicator (LED) illumination condition.

    OK 

    MEASUREMENT CONDITION CHART

    Measurement Condition Specified Condition
    Battery positive (+) → Terminal 5 (ILL+) Indicator (LED) illuminates
    Battery negative (-) → Terminal 3 (E)

    If the result is not as specified, replace the door control switch assembly.

    Fig 2: Identifying Door Control Switch Connector Terminals
    G05765345Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002