Lumbar Switch: Inspection
- INSPECT LUMBAR SWITCH LH
- Measure the resistance according to the value(s) in the table below
Standard Resistance
STANDARD RESISTANCE SPECIFICATIONSTester Connection Switch Condition Specified Condition 3 (B) - 4 (H) Hold Below 1 Ω 1 (R) - 2 (E2) 1 (R) - 2 (E2) Off 4 (H) - 5 (E) 1 (R) - 3 (B) Release 4 (H) - 5 (E) If the result is not as specified, replace the lumbar switch
- Measure the resistance according to the value(s) in the table below
- INSPECT LUMBAR SWITCH RH
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
STANDARD RESISTANCE SPECIFICATIONSTester Connection Switch Condition Specified Condition 3 (B) - 4 (H) Hold Below 1 Ω 1 (R) - 2 (E) 1 (R) - 2 (E) Off 4 (H) - 5 (E) 1 (R) - 3 (B) Release 4 (H) - 5 (E) If the result is not as specified, replace the lumbar switch.
- Measure the resistance according to the value(s) in the table below.