FixVault

Rear Circuit Breaker Sensor: Inspection

  1. INSPECT REAR CIRCUIT BREAKER SENSOR LH 
    1. Measure the resistance according to the value in the table below.

      Standard Resistance 

    RESISTANCE SPECIFIED CONDITIONS

    Tester Connection Specified Condition
    1 (SCR-) - 2 (SCR+) 0.65 to 1.0 kΩ at 20°C (68°F)
    Fig 1: Identifying Terminals Of Rear Circuit Breaker Sensor LH Connector
    G05278992Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  2. INSPECT REAR CIRCUIT BREAKER SENSOR RH 
    1. Measure the resistance according to the value in the table below.

      Standard Resistance 

RESISTANCE SPECIFIED CONDITIONS

Tester Connection Specified Condition
1 (SCR-) - 2 (SCR+) 0.65 to 1.0 kΩ at 20°C (68°F)
Fig 2: Identifying Terminals Of Rear Circuit Breaker Sensor RH Connector
G05278993Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002