Shift Lever Position Sensor: Inspection
- INSPECT PARK/NEUTRAL POSITION SWITCH
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard resistance
RESISTANCE REFERENCEShift Position A8 (+B)-A1 (D) A8 (+B)-A2 (N) A8 (+B)-A3 (P) A8 (+B)-A4 (R) A8 (+B)-A5 (MJ) A8 (+B)-A6 (FD) A8 (+B)-A7 (B) A8 (+B)-A9 (RV) P position 10kΩ or higher 4.2 to 5.1 kΩ Below 1 Ω 10kΩ or higher Below 1 Ω 10kΩ or higher 10kΩ or higher 10kΩ or higher R position 10kΩ or higher 4.2 to 5.1 kΩ 10kΩ or higher Below 1 Ω Below 1 Ω 10kΩ or higher 10kΩ or higher Below 1 Ω N position 10kΩ or higher Below 1 Ω 10kΩ or higher 10 kΩ or higher Below 1 Ω 10 kΩ or higher 10kΩ or higher 10 kΩ or higher D position Below 1 Ω 4.2 to 5.1 kΩ 10kΩ or higher 10 kΩ or higher Below 1 Ω Below 1 Ω 10kΩ or higher 10 kΩ or higher B position 10kΩ or higher 4.2 to 5.1 kΩ 10kΩ or higher 10kΩ or higher Below 1 Ω Below 1 Ω Below 1 Ω 10 kΩ or higher
- Measure the resistance according to the value(s) in the table below.