Roof Position Limit Switch: Inspection
- INSPECT SLIDE ROOF LIMIT SWITCH
- INSPECT SLIDE ROOF LIMIT SWITCH (ROOF CLOSE RH)
- Measure the resistance of the switch.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition 1 - 2 Pushed Below 1 Ω 1 - 2 Not pushed 10 kΩ or higher Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
If the result is not as specified, replace the side roof limit switch.
- Measure the resistance of the switch.
- INSPECT SLIDE ROOF LIMIT SWITCH (ROOF CLOSE LH)
- Measure the resistance of the switch.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition 1 - 2 Pushed Below 1 Ω 1 - 2 Not pushed 10 kΩ or higher Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
If the result is not as specified, replace the side roof limit switch.
- Measure the resistance of the switch.
- INSPECT NO. 1, NO. 2 ROOF POSITION SLIDE ROOF LIMIT SWITCH
- Measure the resistance of the switch (roof position No. 1).
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition 1 - 3 Not pushed Below 1 Ω 1 - 3 Pushed 10 kΩ or higher Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
If the result is not as specified, replace the side roof limit switch.
- Measure the resistance of the switch (roof position No. 2).
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition 2 - 3 Not pushed Below 1 Ω 2 - 3 Pushed 10 kΩ or higher If the result is not as specified, replace the side roof limit switch.
- Measure the resistance of the switch (roof position No. 1).
- INSPECT NO. 3 ROOF POSITION SLIDE ROOF LIMIT SWITCH
- Measure the resistance of the switch.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition 1 - 2 Not pushed Below 1 Ω 1 - 2 Pushed 10 kΩ or higher Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
If the result is not as specified, replace the side roof limit switch.
- Measure the resistance of the switch.
- INSPECT SLIDE ROOF LIMIT SWITCH (ROOF OPEN)
- Measure the resistance of the switch.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition 1 - 2 Not pushed Below 1 Ω 1 - 2 Pushed 10 kΩ or higher Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
If the result is not as specified, replace the side roof limit switch (Roof open).
- Measure the resistance of the switch.