FixVault

Inspection Procedure

  1. INSPECT FUSE (P-IG1-1) 
    1. Remove the P-IG1-1 fuse from the passenger side junction block.
    2. Measure the resistance according to the value (s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFIED CONDITIONS

      Tester Connection Condition Specified Condition
      P-IG1-1 fuse Always Below 1 Ω

      NG: REPLACE FUSE 

      OK: Go to Next Step 

  2. CHECK HARNESS AND CONNECTOR (CLEARANCE WARNING ECU POWER SUPPLY) 
    1. Disconnect the L19 ECU connector.
    2. Measure the resistance according to the value (s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFIED CONDITIONS

      Tester Connection Condition Specified Condition
      15 (IG) - Body ground Always Below 1 Ω
      17 (E) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value (s) in the table below.

      Standard voltage 

      VOLTAGE SPECIFIED CONDITIONS

      Tester Connection Condition Specified Condition
      15 (IG) - 17 (E) Engine switch on (IG) 11 to 14 V
    Fig 1: Identifying L19 Clearance Warning ECU Connector Terminals
    G04951844Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 