Door Control Switch: Inspection
- INSPECT DOOR CONTROL SWITCH ASSEMBLY
- Measure the resistance according to the value(s) in the table below.
Standard resistance
RESISTANCE SPECIFICATIONTester Connection Switch Condition Specified Condition 2(L) - 3(E) Lock Below 1 Ω 2 (L) - 3 (E)
4(UL) - 3(E)OFF 10 kΩ or higher 4(UL) - 3 (E) Unlock Below 1 Ω If the result is not as specified, replace the control switch.
- When terminal 5 (ILL+) of the connector is connected to the positive (+) battery terminal and terminal 3 (E) is connected to the negative (-) battery terminal, check that the indicator (LED) illuminates.
- Measure the resistance according to the value(s) in the table below.