Customize Parameters
- CUSTOMIZING FUNCTION WITH TECHSTREAM (REFERENCE) NOTE:
- When the customer requests a change in a function, first make sure that the function can be customized.
- Be sure to make a note of the current settings before customizing.
- When troubleshooting a function, first make sure that the function is set to the default setting.
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Customize Setting /
- Select the setting by referring to the table below.
Air Conditioner
AIR CONDITIONER REFERENCE CHARTDisplay Default Contents Setting Set Temperature Shift Normal To control with the shifted temperature against the display temperature +2 C/+1 C/Normal/-1 C/-2 C Air Inlet Mode Automatic In case of turning the A/C ON when you desire to make the compartment cool down quickly, this is the function to change the mode automatically to RECIRCULATION mode Manual/Automatic Compressor Mode Automatic Function to turn the A/C ON automatically by pressing the AUTO button when the blower is ON and the A/C is OFF Manual/Automatic Compressor/Air Inlet DEF operation Link Function to turn the A/C ON automatically linked with the FRONT DEF button when A/C is OFF Normal/Link Evaporator Control Automatic Function to set the evaporator control to the AUTOMATIC position (Automatic) to save power, or to the coldest position (Manual) to dehumidify the air and to prevent the windows from fogging up Manual/Automatic Emission Gas Sensor Shift Normal Function to change the sensitivity of the exhaust gas sensor Much More/More/Little More/Normal/Little Less/Less/Much Less Button Press Buzzer ON Function to sound a buzzer when button is pressed OFF/ON Foot/DEF Auto Mode ON Function to turn the airflow from FOOT/DEF ON automatically when AUTO MODE is ON OFF/ON Foot/DEF Automatic Blow Up Function ON Function to change the blower level automatically when the defroster is ON OFF/ON Rear A/PHI Set ON Function to permit the Rear A/P HI Set when AUTO MODE is ON OFF/ON Filter Sensor Normal Function to change the sensitivity of the air conditioning filter clogging sensor Less/Normal/More Ambient Temperature Shift Normal Function to control the shifted ambient temperature in relation to the displayed ambient temperature +3 C/+2 C/+1 C/Normal/-1 C/-2 C/-3 C