FixVault

All Window Switch: Inspection: Inspection

  1. INSPECT SLIDING ROOF SWITCH ASSEMBLY 
    1. Measure the resistance according to the value(s) in the table below.
      Fig 1: Sliding Roof Switch
      GTY355144Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard Resistance

      Tester Connection Switch Condition Specified Condition
      7 (UP) - 6 (E) UP switch pulled up Below 50 Ω
      7 (UP) - 6 (E) UP switch not pulled up 10 kΩ or higher
      8 (DOWN) - 6 (E) DOWN switch pressed halfway down Below 50 Ω
      8 (DOWN) - 6 (E) DOWN switch not pressed 10 kΩ or higher
      4 (AUTO) - 6 (E)
      8 (DOWN) - 6 (E)
      DOWN switch pressed down Below 50 Ω
      4 (AUTO) - 6 (E)
      8 (DOWN) - 6 (E)
      DOWN switch not pressed 10 kΩ or higher
      TEXT IN ILLUSTRATION

      *a Component without harness connected
      (Sliding Roof Switch Assembly)

      If the result is not as specified, replace the sliding roof switch assembly.