All Window Switch: Inspection: Inspection
- INSPECT SLIDING ROOF SWITCH ASSEMBLY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 7 (UP) - 6 (E) UP switch pulled up Below 50 Ω 7 (UP) - 6 (E) UP switch not pulled up 10 kΩ or higher 8 (DOWN) - 6 (E) DOWN switch pressed halfway down Below 50 Ω 8 (DOWN) - 6 (E) DOWN switch not pressed 10 kΩ or higher 4 (AUTO) - 6 (E)
8 (DOWN) - 6 (E)DOWN switch pressed down Below 50 Ω 4 (AUTO) - 6 (E)
8 (DOWN) - 6 (E)DOWN switch not pressed 10 kΩ or higher TEXT IN ILLUSTRATION*a Component without harness connected
(Sliding Roof Switch Assembly)If the result is not as specified, replace the sliding roof switch assembly.
- Measure the resistance according to the value(s) in the table below.