FixVault

Shift Lever: Inspection: Inspection

  1. INSPECT TRANSMISSION CONTROL SWITCH 
    1. Measure the resistance between each terminal of the shift lock control unit assembly when the shift lever is moved to each position.
      Fig 1: Identifying Transmission Control Switch Connector Terminals
      GTY111223Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard resistance

      Tester Connection Shift Lever Position Specified Condition
      3 (IG) - 7 (S) S, "+" and "-" Below 1 Ω
      2 (SFTU) - 5 (E) Continuously held in "+"
      (Up-shift)
      Below 1 Ω
      1 (SFTD) - 5 (E) Continuously held in "-"
      (Down-shift)
      Below 1 Ω
      3 (IG) - 7 (S) Not in S, "+" and "-" 10 kΩ or higher
      2 (SFTU) - 5 (E) S 10 kΩ or higher
      1 (SFTD) - 5 (E) S 10 kΩ or higher

      If the resistance is not as specified, replace the transmission floor shift assembly.