Problem Symptoms Table

HINT: 

Use the table below to help determine the cause of problem symptoms. If multiple suspected areas are listed, the potential causes of the symptoms are listed in order of probability in the "Suspected Area" column of the table. Check each symptom by checking the suspected areas in the order they are listed. Replace parts as necessary.

CLOCK

Symptom Suspected Area See
Clock does not operate at all. Fuse (ECU-ACC, ECU-B, A/C) -
Wire harness or connector -
Center cluster module circuit Refer to REMOVAL
Clock display illumination malfunction Wire Harness or connector -
Combination meter assembly Refer to REMOVAL
Center cluster module circuit Refer to REMOVAL
Clock loses or gains time. Center cluster module circuit Refer to REMOVAL
Clock cannot be adjusted. AVC-LAN circuit (w/ Navigation System (for DVD)) Refer to AVC-LAN Circuit
AVC-LAN circuit (w/ Navigation System (for HDD)) Refer to AVC-LAN Circuit
Display and navigation module display (w/ Navigation System (for DVD)) Refer to REMOVAL
Navigation computer sub-assembly (w/ Navigation System (for HDD)) Refer to REMOVAL
Center cluster module circuit Refer to REMOVAL