On-Vehicle Inspection
- INSPECT DEFOGGER RELAY
- Measure the resistance according to the value(s) in the table below.STANDARD RESISTANCE
Tester Connection Condition Specified Condition 3 - 4 Battery voltage applied between terminals 1 and 2 10 kΩ or higher 3 - 4 Battery voltage not applied between terminals 1 and 2 Below 1 Ω 3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher TEXT IN ILLUSTRATION*1 Component without harness connected
(DEFOGGER Relay)If the result is not as specified, replace the DEFOGGER relay.
- Measure the resistance according to the value(s) in the table below.
- INSPECT DEICER RELAY
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
STANDARD RESISTANCETester Connection Condition Specified Condition 3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher TEXT IN ILLUSTRATION*1 Component without harness connected
(DEICER Relay)If the result is not as specified, replace the DEICER relay.
- Measure the resistance according to the value(s) in the table below.