Monitor Strategy

Related DTCs P0101: Mass air flow meter rationality
Required Sensors/Components (Main) Mass air flow meter
Required Sensors/Components (Related) Crankshaft Position (CKP) sensor, VVT sensor, Engine Coolant Temperature (ECT) sensor and Throttle Position (TP) sensor
Frequency of Operation Continuous
Duration 10 times
MIL Operation 2 driving cycles
Sequence of Operation None