Valve Body Assembly: Inspection: Inspection

  1. INSPECT SHIFT SOLENOID VALVE SL1 
    Fig 1: Inspecting Shift Solenoid Valve SL1
    GTY289407Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK

      Measurement Condition Specified Condition
      Battery positive (+) with a 21 W bulb → Terminal 2
      Battery negative (-) → Terminal 1
      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  2. INSPECT SHIFT SOLENOID VALVE SL2 
    Fig 2: Inspecting Shift Solenoid Valve SL2
    GTY254597Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK

      Measurement Condition Specified Condition
      Battery positive (+) with a 21 W bulb → Terminal 2
      Battery negative (-) → Terminal 1
      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  3. INSPECT SHIFT SOLENOID VALVE SL3 
    Fig 3: Inspecting Shift Solenoid Valve SL3
    GTY253969Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK

      Measurement Condition Specified Condition
      Battery positive (+) with a 21 W bulb → Terminal 2
      Battery negative (-) → Terminal 1
      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  4. INSPECT SHIFT SOLENOID VALVE SL4 
    Fig 4: Inspecting Shift Solenoid Valve SL4
    GTY289408Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK

      Measurement Condition Specified Condition
      Battery positive (+) with a 21 W bulb → Terminal 2
      Battery negative (-) → Terminal 1
      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  5. INSPECT SHIFT SOLENOID VALVE SL5 
    Fig 5: Inspecting Shift Solenoid Valve SL5
    GTY255261Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Measure the resistance according to the value(s) in the table below.

      OK

      Measurement Condition Specified Condition
      Battery positive (+) with a 21 W bulb → Terminal 2
      Battery negative (-) → Terminal 1
      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  6. INSPECT SHIFT SOLENOID VALVE SL 
    Fig 6: Inspecting Shift Solenoid Valve
    GTY348974Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      Shift solenoid valve connector - Shift solenoid valve body 20°C (68°F) 11 to 15 Ω
    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK

      Measurement Condition Specified Condition
      Battery positive (+) → Shift solenoid valve connector
      Battery negative (-) → Shift solenoid valve body
      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  7. INSPECT SHIFT SOLENOID VALVE SLU 
    Fig 7: Inspecting Shift Solenoid Valve SLU
    GTY255081Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK

      Measurement Condition Specified Condition
      Battery positive (+) with a 21 W bulb → Terminal 1
      Battery negative (-) → Terminal 2
      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  8. INSPECT SHIFT SOLENOID VALVE SLT 
    Fig 8: Inspecting Shift Solenoid Valve SLT
    GTY255284Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK

      Measurement Condition Specified Condition
      Battery positive (+) with a 21 W bulb → Terminal 2
      Battery negative (-) → Terminal 1
      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  9. INSPECT SHIFT SOLENOID VALVE SR 
    Fig 9: Inspecting Shift Solenoid Valve
    GTY353374Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      Shift solenoid valve connector - Shift solenoid valve body 20°C (68°F) 11 to 15 Ω
    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK

      Measurement Condition Specified Condition
      Battery positive (+) → Shift solenoid valve connector
      Battery negative (-) → Shift solenoid valve body
      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.