FixVault

Typical Enabling Conditions

ALL

Monitor runs whenever the following DTCs are not stored None
COLD START MONITOR

All of the following conditions are met -
Auxiliary battery voltage 10.5 V or higher
Time after engine start 1 second or more
Engine coolant temperature at engine start Less than 60°C (140°F)
Soak time 0 second or more
Accumulated mass air flow 2013 g or more
Fuel cut Off
Intake air temperature sensor circuit fail (P0112, P0113) Not detected
Engine coolant temperature sensor circuit fail (P0115, P0117, P0118, P0125) Not detected
Engine water pump circuit fail (P261B, P261C, P261D) Not detected
Thermostat fail (P0128) Not detected
Difference between engine coolant temperature at engine start and intake air temperature Less than 40°C (72°F)
SOAK MONITOR

All of the following conditions are met -
Auxiliary battery voltage 10.5 V or higher
Engine Running
Soak time 5 hours or more
Either of the following condition is met 1 or 2
1. Engine coolant temperature 60°C (140°F) or higher
2. Accumulated mass air flow 4026 g or more
Intake air temperature sensor circuit fail (P0112, P0113) Not detected
Engine coolant temperature sensor circuit fail (P0115, P0117, P0118, P0125) Not detected
Engine water pump circuit fail (P261B, P261C, P261D) Not detected
Thermostat fail (P0128) Not detected
Soak timer circuit fail (P2610) Not detected