FixVault

Inspection [09/2015 - ]: Procedure

  1. INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY 
    1. Measure the resistance according to the value(s) in the table below.
      GTY637826Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      STANDARD RESISTANCE

      Tester Connection Switch Condition Specified Condition
      8 (P) - 1 (E) SPORT S or SPORT S+ mode switch turned and held at SPORT S or SPORT S+ position Below 1 Ω
      SPORT S or SPORT S+ mode switch not turned 10 kΩ or higher
      6 (ECU) - 1 (E) COMF or ECO mode switch turned and held at COMF or ECO position Below 1 Ω
      COMF or ECO mode switch not turned 10 kΩ or higher
      19 (2nd) - 1 (E) Mode switch (ECT 2nd) on Below 1 Ω
      Mode switch (ECT 2nd) off 10 kΩ or higher
      7 (B) - 1 (E) NORMAL mode switch pushed and held Below 1 Ω
      NORMAL mode switch not pushed 10 kΩ or higher
      TEXT IN ILLUSTRATION

      *a Component without harness connected
      (Integration Control and Panel Assembly)

      If the result is not as specified, replace the integration control and panel assembly.