Inspection [08/2014 - ]: Procedure

  1. INSPECT CRANK POSITION SENSOR 
    1. Measure the resistance according to the value(s) in the table below.
      GTY336963Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      TEXT IN ILLUSTRATION

      *1 Ohmmeter

      Standard Resistance

      Tester Connection Condition Specified Condition
      1 - 2 -10 to 50°C (14 to 122°F) 1630 to 2740 Ω
      50 to 100°C (122 to 212°F) 2065 to 3225 Ω