FixVault

Installation [10/2015 - ]: Procedure

  1. INSTALL YAW RATE SENSOR BRACKET 
    1. Engage the 2 hooks to install the yaw rate sensor bracket with the 2 screws.

      Torque: 12.5 N*m (127 kgf*cm, 9 ft.*lbf) 

  2. INSTALL ROLL RATE AND VERTICAL ACCELERATION SENSOR (YAW RATE SENSOR) 
    1. Install the roll rate and vertical acceleration sensor (yaw rate sensor) with the 2 nuts.

      Torque: 9.0 N*m (92 kgf*cm, 80 in.*lbf) 

      NOTE:
      • Do not drop the roll rate and vertical acceleration sensor (yaw rate sensor).
      • If the roll rate and vertical acceleration sensor (yaw rate sensor) is dropped, replace it with a new one.
    2. Connect the connector to the roll rate and vertical acceleration sensor (yaw rate sensor).
      NOTE:

      Make sure that the roll rate and vertical acceleration sensor (yaw rate sensor) connector is connected securely.

  3. INSTALL INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY 

    Refer to INSTALLATION [10/2015 - ]

  4. INSTALL CONSOLE BOX ASSEMBLY 

    Refer to INSTALLATION [10/2015 - ]

  5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL 

    Refer to PROCEDURE - Step 2

    NOTE:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Refer to INITIALIZATION [10/2015 - 09/2016] , or Refer to INITIALIZATION [09/2016 - 09/2017] , or Refer to INITIALIZATION [09/2017 - ]

  6. PERFORM YAW RATE AND ACCELERATION SENSOR AND ROLL RATE AND VERTICAL ACCELERATION SENSOR ZERO POINT CALIBRATION 

    Refer to CALIBRATION [10/2015 - 09/2017] , or Refer to CALIBRATION [09/2017 - ]