Inspection [12/2017 - ]: Procedure
- INSPECT NO. 2 SATELLITE SWITCH SET (VSC OFF SWITCH)
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(No. 2 Satellite Switch Set (VSC OFF Switch))Standard Resistance
Tester Connection Condition Specified Condition G59-2(+) - G59-7(E) Switch pushed Below 50 Ω G59-2(+) - G59-7(E) Switch not pushed 10 kΩ or higher If the result is not as specified, replace the No. 2 satellite switch set (VSC OFF switch).
- Apply battery voltage to the connector and check the illumination conditions.
OK
Measurement Condition Specified Condition Battery positive (+) → G59-1(ILL+)
Battery negative (-) → G59-8(ILL-)Illuminates *a Component without harness connected
(No. 2 Satellite Switch Set (VSC OFF Switch))If the result is not as specified, replace the No. 2 satellite switch set (VSC OFF switch).
- Measure the resistance according to the value(s) in the table below.