FixVault

Service Data [06/2018 - ]: Relay

RELAY

Standard Resistance
(Main Relay (EFI-MAIN NO. 1))
3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Battery voltage applied between terminals 1 and 2 Below 1 Ω
Standard Resistance
(Main Relay (EFI-MAIN NO. 2))
3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Battery voltage applied between terminals 1 and 2 Below 1 Ω
Standard Resistance
(Main Relay (A/F HTR))
3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Battery voltage applied between terminals 1 and 2 Below 1 Ω
Standard Resistance
(Electronic driver unit relay (D INJ))
3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Battery voltage applied between terminals 1 and 2 Below 1 Ω
Standard Resistance
No. 2 ignition relay (IG2 NO. 1)
3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Battery voltage applied between terminals 1 and 2 Below 1 Ω