Inspection [07/2020 - ]: Procedure
- INSPECT VSC OFF SWITCH (NO. 2 COMBINATION SWITCH ASSEMBLY)
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(VSC OFF Switch (No. 2 Combination Switch Assembly))Standard Resistance
Tester Connection Condition Specified Condition 8 (+) - 1 (E) Switch pushed Below 50 Ω Switch not pushed 10 kΩ or higher If the result is not as specified, replace the VSC OFF switch (No. 2 combination switch assembly).
- Apply battery voltage to the connector and check the illumination conditions.
OK
Measurement Condition Specified Condition Battery positive (+) → 10 (ILL+)
Battery negative (-) → 6 (ILL-)Illuminates *a Component without harness connected
(VSC OFF Switch (No. 2 Combination Switch Assembly))If the result is not as specified, replace the VSC OFF switch (No. 2 combination switch assembly).
- Measure the resistance according to the value(s) in the table below.