Check Valve
Connect a vacuum supply to Black side of check valve. Connect a vacuum gauge to opposite side. Vacuum gauge should read instantly. Reverse connections. Vacuum gauge should not read vacuum. Replace valve if it fails either test.
Connect a vacuum supply to Black side of check valve. Connect a vacuum gauge to opposite side. Vacuum gauge should read instantly. Reverse connections. Vacuum gauge should not read vacuum. Replace valve if it fails either test.