Installation (Later Design)
- Install distributor in engine so that slot on distributor base hold-down flange is aligned with clamp bolt hole in block.
- The large slot in distributor sleeve assembly should be approximately aligned with slot in adapter.
- If alignment is not possible, raise distributor and rotate distributor shaft slightly to allow next tooth of distributor drive gear to engage cam gear. Install hold-down clamp.
- Align sleeve and install distributor cap following rotor installation procedures.