FixVault

Front Auxiliary Climate Control Assembly

Fig 1: Identifying Front Auxiliary Climate Control Assembly Pins
G03859558Courtesy of FORD MOTOR CO.
BLOWER MODE, AIRFLOW MODE AND PINS FOR CONTINUITY

Blower Mode Airflow Mode Continuity between pins
HIGH FLOOR 4 and 9, 2 and 10
HIGH PANEL 4 and 10, 2 and 9
REAR FLOOR/PANEL 10 and 7, 4 and 5
REAR FLOOR/PANEL 2 and 1, 3 and 8
FRONT AUXILIARY CLIMATE CONTROL ASSEMBLY PINS RESISTANCE RANGE

Resistance between pins Resistance range (approx.)
3 and 9 50 ohms (WARM)-3,000 ohms (COOL)
3 and 10 50 ohms (COOL)-3,000 ohms (WARM)