FixVault

Removal And Installation

  1. Disconnect the mass air flow (MAF) sensor electrical connector.
  2. Remove the 2 screws and the MAF sensor.
    • To install, tighten to 2 Nm (18 lb-in).
  3. To install, reverse the removal procedure.