FixVault

Removal and Installation

  1. NOTE: It is necessary to record the current Accessory Protocol Interface Module (APIM) software and hardware level when a new APIM  is being installed to make sure that the new component is the same version as the component being replaced.

    Retrieve and record the current APIM  software and hardware level. For additional information, refer to ACCESSORY PROTOCOL INTERFACE MODULE (APIM) SOFTWARE LEVEL CHECK .

  2. Remove the floor console. For additional information, refer to INSTRUMENT PANEL AND CONSOLE .
  3. Remove the floor console rear panel by pulling straight back to disengage the clips.
    • Disconnect the electrical connectors.
  4. Remove the LH and RH floor console upper trim panels.
    • Using a suitable tool such as a trim removal tool, disengage the clips.
  5. Remove the 4 screws and the APIM  bracket and APIM  as an assembly.
    • Disconnect the electrical connector.
    • Disconnect the Universal Serial Bus (USB) cable.
  6. Remove the 4 screws and separate the APIM  from the bracket.
  7. To install, reverse the removal procedure.
    • If a new APIM  is being installed, program the APIM  to the correct software level. For additional information, refer to MODULE CONFIGURATION .