FixVault

Generator Current Sensor: Installation

  1. With the generator current sensor tape tab pointing upward, position the generator current sensor to the index-mark on the battery cable and secure with electrical tape.
    NOTE: The generator current sensor must be installed in the proper position and orientation to function correctly.
  2. Connect the generator current sensor electrical connector.
  3. Connect the positive battery cable terminal to the battery terminal and install the battery terminal nut.
    • Tighten to 9 Nm (80 lb-in).
  4. Connect the battery. For additional information, refer to BATTERY DISCONNECT .