FixVault

Accelerator Pedal: Removal

NOTE: Removal steps in this procedure may contain installation details.
    1. Remove the push pin.
    2. Remove the retainers.

      Torque

      : 35 lb.in (4 Nm)

    3. Disconnect the electrical connector and remove the LH insulation panel.
    GFD164721Courtesy of FORD MOTOR COMPANY
  1. NOTE: To prevent setting DTC make sure the ignition is in the OFF position prior to disconnecting the accelerator pedal electrical connector.

    Disconnect the electrical connector, remove the nuts and the accelerator pedal assembly.

    Torque

    : 71 lb.in (8 Nm)

GFD166827Courtesy of FORD MOTOR COMPANY