FixVault

Camshaft Runout

Special Tool(s) 

GFD91010Courtesy of FORD MOTOR COMPANY
Dial Indicator Gauge with Holding Fixture 100-002 (TOOL-4201-C) or equivalent
NOTE: Refer to the appropriate information for the specification.
  1. NOTE: Camshaft journals must be within specifications before checking runout.

    Using the Dial Indicator Gauge with Holding Fixture, measure the camshaft runout.

    • Camshaft must be supported on the first and last camshaft bearing journal.
    • Rotate the camshaft and subtract the lowest Dial Indicator Gauge reading from the highest Dial Indicator Gauge reading.
GFD91324Courtesy of FORD MOTOR COMPANY