FixVault

Heated Oxygen Sensor (HO2S) 3.5L GTDI: Installation

RH sensor 

  1. Apply the specified lubricant to the specified component. High Temperature Nickel Anti-Seize Lubricant XL-2. Special Tool(s): Socket, Exhaust Gas Oxygen Sensor 303-476 (T94P-9472-A).
    • Calculate the correct torque wrench setting for the following torque. Refer to the Torque Wrench Adapter Formulas below.
      G00468730Courtesy of FORD MOTOR COMPANY
    • Tighten to 48 Nm (35 lb-ft).
    GFD92933Courtesy of FORD MOTOR COMPANY
  2. GFD92929Courtesy of FORD MOTOR COMPANY
  3. LH sensor 

  4. Apply the specified lubricant to the specified component. High Temperature Nickel Anti-Seize Lubricant XL-2. Special Tool(s): Socket, Exhaust Gas Oxygen Sensor 303-476 (T94P-9472-A).
    • Calculate the correct torque wrench setting for the following torque. Refer to the Torque Wrench Adapter Formulas below.
      G00468730Courtesy of FORD MOTOR COMPANY
    • Tighten to 48 Nm (35 lb-ft).
    GFD92934Courtesy of FORD MOTOR COMPANY
  5. GFD91394Courtesy of FORD MOTOR COMPANY
  6. GFD92931Courtesy of FORD MOTOR COMPANY