FixVault

Man. Trans. Equipped Models

Disconnect idle switch. Check continuity between numbered terminals. See Figure. With engine at idle, continuity should exist between terminals No. 1 and 3, with no continuity between terminals No. 1 and 2. Increase engine speed to 1000 RPM. Continuity should exist between terminals No. 1 and 2, with no continuity between terminals No. 1 and 3.