FixVault

Airflow Meter (AFM)

Inspect airflow meter body for cracks or damage. Using an ohmmeter, check resistance between sensor terminals. See AIRFLOW METER SPECIFICATIONS  table. Pry open measuring plate with a screwdriver and measure resistance between terminals "E1" and "Fc" (fuel pump switch), and between terminals "E2" and "Vs". See Fig 1 . If readings are incorrect replace AFM assembly.

AIRFLOW METER SPECIFICATIONS

Terminal Resistance (Ohms)
E2-Vs 20-400
E2-Vc 100-300
E2-Vb 200-400
E2-THA (At Temperature Indicated)
-4°F (-20°C) 10,000-20,000
0°F (0°C) 4000-7000
68°F (20°C) 900-1300
140°F (60°C) 400-700
E1-Fc Infinity
E1-FC Measuring Plate Fully Closed Infinity
E1-FC Measuring Plate Fully Open 0
E2-VS Measuring Plate Fully Closed 20-400
E2-VS Measuring Plate Fully Open 20-1000
Fig 1: Measuring Airflow Meter Resistance
G48204