FixVault

Crank Angle Sensor

Disconnect crank angle sensor connector. Connect circuit tester to crank angle sensor connnector terminals. Check resistance between "G1" and "G2" terminals and "Ne1" and "Ne2" terminals. Resistance should be 110-210 ohms. See Fig 1.

Fig 1: Crank Angle Sensor Connector Locations
G34344