  1. Remove air cleaner cover and place thermometer near sensor. Using a heat lamp, heat intake air temperature sensor and observe temperature on thermometer. Using a ohmmeter, check resistance between terminals "THA" and "E2". See INTAKE AIR TEMPERATURE SENSOR SPECIFICATION table.
  2. If readings are not within specifications, replace airflow meter assembly. If readings are correct, check wiring harness for short or open circuits.
INTAKE AIR TEMPERATURE SENSOR SPECIFICATIONS

Air Temperature °F (°C) Resistance (Ohms)
-4 (-20) 13,600-18,400
68 (20) 2205-2690
140 (60) 493-667