FixVault

Purge Solenoid

  1. Disconnect vacuum hose from solenoid. See Fig 1 . Blow through port A. Ensure air exhausts through port C.
  2. Disconnect 2 wire connector from solenoid. Connect 12 volts to one terminal and ground the other terminal of solenoid. Blow air though port "A". Ensure air exhausts through port "B".
Fig 1: Purge Solenoid
G94797Courtesy of MAZDA MOTORS CORP.