Turbocharger Air By-Pass Valve
Remove air by-pass valve. Connect vacuum pump to port "A" of valve. Apply vacuum to port "A" and compressed air to port "B". See Fig 1 . Verify air flows through valve with prescribed vacuum applied to port "A". See AIR BY-PASS VALVE VACUUM SPECIFICATION table. Replace air by-pass valve if it does not operate as indicated.
AIR BY-PASS VALVE VACUUM SPECIFICATIONS
| Application | Inch Hg |
|---|---|
| MX-6 & 626 | 9.8-15.7 |