FixVault

Function Test

Start engine to supply vacuum to actuator diaphragm. Observe actuator arm when battery voltage is connected across specified terminals of actuator connector. SeeFigure . If actuator arm does not function as specified, replace actuator.

ACTUATOR FUNCTION TEST

Application Actuator Arm Result
Apply 12 Volts To Terminal "C"
& Ground Terminals "A", "B" & "D" Pull
Apply 12 Volts To Terminal "C"
& Ground Terminals "A" & "D" Hold
Apply 12 Volts To Terminal "C"
& Ground Terminal "A" Extend
Disconnect All Voltage & Ground Release