Door Key Cylinder Switch

Remove door trim panel. Disconnect door key cylinder switch connector. Check continuity between switch connector terminals. With door key cylinder turned to unlocked position, there should be continuity. With door key cylinder in any other position, there should be no continuity. If continuity is not as specified, replace switch.