Door Lock Link Switch
Remove door trim panel. Disconnect door lock link switch connector. Ensure continuity exists between specified terminals of door lock link switch connector with switch in specified position. See DOOR LOCK LINK SWITCH CONTINUITY TEST table. If there is no continuity, replace door lock mechanism.
DOOR LOCK LINK SWITCH CONTINUITY TEST
| Application & Switch Position | Terminals |
|---|---|
| Locked | Blue/Red & Green/Red |
| Unlocked | Blue/Red & Green/Orange |