Brush Test
- Connect ohmmeter lead to positive brush holder and other lead to negative brush holder. If continuity exists, brush holder assembly is shorted and must be replaced.
- Check brush length. Standard brush length is .67" (17.0 mm). Minimum brush length is .45" (11.5 mm). If length is less than specified, replace brushes.
- Using brush spring scale, measure spring tension. Tension should be greater than 2 lbs. (0.9 kg). Tension for a NEW spring should be 3.1-5.7 lbs. (1.4-2.6 kg). Ensure brushes move freely in holders.