FixVault

Symptom No. 4

Turn ignition on. Turn power cut switch to ON position. Measure voltage at Black/Blue wire terminal of main switch connector. If battery voltage is not present, check main switch. See MAIN SWITCH TEST  under COMPONENT TESTING. If battery voltage is present, measure voltage at Black/Blue wire terminal of each sub-switch connector. If battery voltage is not present, repair wiring between main switch and sub-switch. If battery voltage is present, check sub-switch. See SUB-SWITCH TEST  under COMPONENT TESTING.