Continuity Test

  1. Disconnect hydraulic unit connector. Using a DVOM, measure continuity between following wires: Yellow/Green wire and Green/Yellow wire; Brown wire and Green/Yellow wire; Black/White wire and Green/Yellow wire. See Figure . Continuity should be present in each measurement.
  2. If continuity is not present, replace hydraulic unit. If continuity is present, check wiring harness between ABS control unit and hydraulic unit. Repair or replace if necessary.