Heat Hazard Sensor

  1. Remove right front seat. Lift floor mat and remove heat hazard sensor. Wrap sensor and a thermometer in aluminum foil. Place foil in a pot of oil. Connect a battery and 12-volt test light in series, to sensor terminals.
  2. Heat oil to 221-239°F (105-115°C). Test light should light when sensor reaches specified temperature. If test light does not light, replace heat hazard sensor.