FixVault

Test No. 9

  1. Turn hazard lights on. If hazard lights do not illuminate, repair hazard lights circuit. If hazard lights illuminate, go to next step.
  2. Turn hazard lights off. Measure voltage at terminal 1E (Green/Yellow wire) of CPU 16-pin connector. SeeFigure . If battery voltage does not exist, repair wiring between flasher unit and CPU. If battery voltage exists, replace CPU.