FixVault

SANDEN - Scroll: Protege

Drain and measure oil from old compressor. Add amount drained plus 0.2-0.3 ounce of new refrigerant oil to replacement compressor. If any other major components are replaced, add refrigerant oil as specified. See COMPONENT REFRIGERANT OIL CAPACITIES (SANDEN)  table.

COMPONENT REFRIGERANT OIL CAPACITIES (SANDEN)

Component Ounces
Compressor (1) 4.1
Condenser 0.5
Evaporator 1.7
Receiver-Drier 0.3
Refrigerant Lines 0.3
(1) If new compressor is shipped without refrigerant oil, add same amount of new refrigerant oil to new compressor that was drained from old compressor.