Function Test

Start engine to supply vacuum to actuator diaphragm. On all models, observe actuator arm when battery voltage is applied across specified terminals of actuator connector. See ACTUATOR FUNCTION TEST  . SeeFigure . If actuator arm does not function as specified, replace actuator.

ACTUATOR FUNCTION TEST

Application Actuator Arm Result
Apply 12 Volts To Pin "C" & Ground Pins "A", "B" & "D" Pull
Apply 12 Volts To Pin "C" & Ground Pins "A" & "D" Hold
Apply 12 Volts To Pin "C" & Ground Pin "A" Extend
Disconnect All Voltage & Ground Release