With Valve Relay Installed

Turn ignition off. Disconnect hydraulic unit 12-pin connector. See COMPONENT LOCATIONS  . Apply 12 volts to terminal "A" and ground terminal "D" of hydraulic unit 12-pin connector. See Figure . Using ohmmeter, measure resistance between terminal "B" and specified terminals of hydraulic unit connector. See HYDRAULIC UNIT CONNECTOR TERMINAL RESISTANCE  table. If resistance is not as specified, check solenoid valves with vale relay removed. See WITH VALVE RELAY REMOVED. Also check valve relay. See VALVE RELAY.

HYDRAULIC UNIT CONNECTOR TERMINAL RESISTANCE

Terminal Ohms
"H" 4.7
"I" 4.7
"J" 4.7
"M" 9
"N" 9
"O" 9