FixVault

Function Test

Disconnect actuator cable from accelerator. Start engine to supply vacuum to actuator diaphragm. SeeFigure . Apply battery voltage and ground to specified terminals of actuator and observe actuator arm. See ACTUATOR FUNCTION TEST  . If actuator arm does not function as specified, replace actuator.

ACTUATOR FUNCTION TEST

Application/Terminals Actuator Arm Result
Apply 12 Volts To "C" & Ground "A", "B" & "D" Pull
Apply 12 Volts To "C" & Ground "A" & "D" Hold
Apply 12 Volts To "C" & Ground "A" Extend
Disconnect All Voltage & Ground Release